Actively exploited KEV catalog No authentication
CVE-2023-4346

KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices…

CheckOps priority index
4.8/10 Patch within 7 days
Severity7.5
Probability0.1
Exploitation3/5

Severity = CVSS. Probability = EPSS (FIRST). Exploitation = public signals: KEV, EUVD, ransomware, EPSS above 10 %, no account required.

EPSS · today 1.4% higher than 71.8% of CVEs
CVSS 3.1 7.5 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:
Exploited for 111 days 15 Jul 2026
CISA due date 29 Jul 2026 for US federal agencies

Exploitation probability EPSS · FIRST

05010026 Sep05 Oct15 Oct24 Oct02 Nov
EPSS probability (%)Percentile among all CVEs

Exploitation signals 3 / 5

  • KEV catalog (CISA)15 Jul 2026
  • Exploited in EUVD (ENISA)15 Jul 2026
  • Used by ransomwareno
  • EPSS above 10 %1.4%
  • No account, over the networkyes

What to do

Fix

Apply the vendor’s fix as soon as it is available.

CISA guidance: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

Meanwhile

Take the service off the internet or restrict access to it, watch the logs and look for signs of compromise.

Manufacturers (CRA)

Exploited vulnerability in your product: early warning to ENISA within 24 h, then notification within 72 h (Article 14 of the Cyber Resilience Act). The CRA explained

Description ENISA EUVD

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.

Affected products

KNX Protocol Connection Authorization Option 1
Affected versions
  • 0
Weaknesses (CWE)

Open source packages OSV

Affected libraries according to OSV, with fixed versions.

Timeline

  1. Published

  2. Exploitation reported (ENISA)

  3. Added to the KEV catalog

  4. CISA remediation due date

References

Are you affected?

CheckOps reads your SBOMs and scans, and alerts you as soon as one of your dependencies is exploited.

Get notified at launch