KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability
KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices…
Schweregrad = CVSS. Wahrscheinlichkeit = EPSS (FIRST). Ausnutzung = öffentliche Signale: KEV, EUVD, Ransomware, EPSS über 10 %, ohne Konto.
Ausnutzungswahrscheinlichkeit EPSS · FIRST
Ausnutzungssignale 3 / 5
- KEV-Katalog (CISA)15.07.2026
- In der EUVD ausgenutzt (ENISA)15.07.2026
- Von Ransomware genutztnein
- EPSS über 10 %1,4 %
- Ohne Konto, über das Netzja
Was tun
Beheben
Den Patch des Herstellers einspielen, sobald er verfügbar ist.
Vorgabe der CISA: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Bis dahin
Den Dienst vom Internet nehmen oder den Zugriff einschränken, Protokolle überwachen und nach Kompromittierungsspuren suchen.
Hersteller (CRA)
Ausgenutzte Schwachstelle in Ihrem Produkt: Frühwarnung an die ENISA binnen 24 h, dann Meldung binnen 72 h (Artikel 14 des Cyber Resilience Act). Der CRA erklärt
Beschreibung ENISA EUVD
KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.
Text der Quelle, auf Englisch.
Betroffene Produkte
- 0
Open-Source-Pakete OSV
Betroffene Bibliotheken laut OSV, mit behobenen Versionen.
Zeitverlauf
-
Veröffentlichung
-
Ausnutzung gemeldet (ENISA)
-
Aufnahme in den KEV-Katalog
-
CISA-Frist zur Behebung